Undecim genera pathogenorum respiratoriorum
Nomen producti
HWTS-RT162A Instrumentum ad Undecim Genera Pathogenorum Respiratoriorum Acidorum Nucleicorum Detegendum(PCR fluorescentiae)
Canalis
靶标 | Canalis | |||
A | B | C | D | |
HI | Smet | MP | Crus | FAM |
SP | PA | Bp | / | CY5 |
KPN | ABA | Bpp | Cuponem | ROX |
内参 | 内参 | 内参 | 内参 | VIC/HEX |
Epidemiologia
Infectiones tractus respiratorii sunt classis morborum magni momenti quae gravem minam valetudini humanae afferunt, et studia demonstraverunt plerasque infectiones tractus respiratorii a pathogenis bacterialibus et/vel viralibus hospitem co-infecentibus causari, quod ad maiorem gravitatem morbi et etiam mortem ducit, ergo clarificatio pathogeni curationem directam permittit et ratam supervivendi aegroti auget.[1,2].
Parametri Technici
Repositorium | ≤-18℃ |
Tempus conservationis | Duodecim menses |
Typus Speciminis | Sputum |
Ct | Altus, SP, KPN, PA, ABA, Smet: Ct≤33BP, Bpp, MP, Cpn, Crus: Ct ≤38 |
CV | <5.0% |
Limitatio Detectionis (vel Limitatio Detectionis) | Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonas.aeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia et Legionellapneumophila: 1000 CFU/mL; Bordetella pertussis et Bacillus parapertussis: 500 CFU/mL; Mycoplasma pneumoniae et Chlamydia pneumoniae: 200 exemplaria/mL. |
Specificitas | Resultata probationis reactionis transversalis demonstraverunt nullam reactionem transversalem inter hoc instrumentum et Cytomegalovirus, virus Herpes simplex typus 1, virus Varicella-zoster, virus Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillum, Legionella pneumophila, Moraxella catarrhalis, stirpes attenuatas Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida exstitisse. *Antibacterium albicans*, *Rothia mucilaginosa*, *Streptococcus oralis*, *Klebsiella pneumoniae*, *Chlamydia psittaci*, *Coxiella burnetii* et acida nucleica genomica humana. |
Instrumenta Applicabilia | Systema PCR Temporis Realis 7500 Biosystems Applied Systema PCR Temporis Realis Celeris Applied Biosystems 7500 QuantStudio®Quinque Systemata PCR Temporis Realis Systema PCR Temporis Realis SLAN-96P Cyclus Lucis®Systema PCR in Tempore Reali 480 Systema Detectionis PCR in Tempore Reali LineGene 9600 Plus MA-6000 Cyclator Thermalis Quantitativus Temporis Realis Systema PCR Temporis Realis BioRad CFX96 Systema PCR Temporis Realis BioRad CFX Opus 96 |
Fluxus Operis
Instrumentum Generale Macro & Micro-Test DNA/RNA (HWTS-3019) (quod cum Extractore Automatico Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B) adhiberi potest) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Adde 200µL...physiologicusSolutionem salinam ad praecipitatum processum adde, et gradus subsequentes secundum instructiones peragendi sunt. Volumen elutionis commendatum est 100 µL.