Undecim genera pathogenorum respiratoriorum

Descriptio Brevis:

Hoc instrumentum adhibetur ad detectionem qualitativam *in vitro* pathogenorum clinicorum respiratoriorum communium in sputo humano, inter quae *Haemophilus influenzae* (HI), *Streptococcus pneumoniae* (SP), *Acinetobacter baumannii* (ABA), *Pseudomonas aeruginosa* (PA), *Klebsiella pneumoniae* (KPN), *Stenotrophomonas maltophilia* (Smet), *Bordetella pertussis* (BP), *Bacillus parapertusss* (Bpp), *Mycoplasma pneumoniae* (MP), *Chlamydia pneumoniae* (Cpn), et *Legionella pneumophila* (Leg). Resultata adhiberi possunt ut auxilium in diagnosi aegrotorum hospitalizatorum vel graviter aegrotorum cum suspicione infectionum bacterialium tractus respiratorii.Hoc instrumentum adhibetur ad detectionem qualitativam *in vitro* pathogenorum clinicorum respiratoriorum communium in sputo humano, inter quae *Haemophilus influenzae* (HI), *Streptococcus pneumoniae* (SP), *Acinetobacter baumannii* (ABA), *Pseudomonas aeruginosa* (PA), *Klebsiella pneumoniae* (KPN), *Stenotrophomonas maltophilia* (Smet), *Bordetella pertussis* (BP), *Bacillus parapertusss* (Bpp), *Mycoplasma pneumoniae* (MP), *Chlamydia pneumoniae* (Cpn), et *Legionella pneumophila* (Leg). Resultata adhiberi possunt ut auxilium in diagnosi aegrotorum hospitalizatorum vel graviter aegrotorum cum suspicione infectionum bacterialium tractus respiratorii.


Detalia Producti

Etiquettae Productarum

Nomen producti

HWTS-RT162A Instrumentum ad Undecim Genera Pathogenorum Respiratoriorum Acidorum Nucleicorum Detegendum(PCR fluorescentiae)

Canalis

靶标 Canalis
A B C D
HI Smet MP Crus FAM
SP PA Bp / CY5
KPN ABA Bpp Cuponem ROX
内参 内参 内参 内参 VIC/HEX

Epidemiologia

Infectiones tractus respiratorii sunt classis morborum magni momenti quae gravem minam valetudini humanae afferunt, et studia demonstraverunt plerasque infectiones tractus respiratorii a pathogenis bacterialibus et/vel viralibus hospitem co-infecentibus causari, quod ad maiorem gravitatem morbi et etiam mortem ducit, ergo clarificatio pathogeni curationem directam permittit et ratam supervivendi aegroti auget.[1,2].

Parametri Technici

Repositorium

≤-18℃

Tempus conservationis Duodecim menses
Typus Speciminis Sputum
Ct Altus, SP, KPN, PA, ABA, Smet: Ct≤33BP, Bpp, MP, Cpn, Crus: Ct ≤38
CV <5.0%
Limitatio Detectionis (vel Limitatio Detectionis) Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, Pseudomonas.aeruginosa, Acinetobacter baumannii, Stenotrophomonas maltophilia et Legionellapneumophila: 1000 CFU/mL

Bordetella pertussis et Bacillus parapertussis: 500 CFU/mL;

Mycoplasma pneumoniae et Chlamydia pneumoniae: 200 exemplaria/mL.

Specificitas Resultata probationis reactionis transversalis demonstraverunt nullam reactionem transversalem inter hoc instrumentum et Cytomegalovirus, virus Herpes simplex typus 1, virus Varicella-zoster, virus Epstein-Barr, Bordetella pertussis, Corynebacterium, Escherichia coli, Haemophilus influenzae, Lactobacillum, Legionella pneumophila, Moraxella catarrhalis, stirpes attenuatas Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida exstitisse. *Antibacterium albicans*, *Rothia mucilaginosa*, *Streptococcus oralis*, *Klebsiella pneumoniae*, *Chlamydia psittaci*, *Coxiella burnetii* et acida nucleica genomica humana.
Instrumenta Applicabilia Systema PCR Temporis Realis 7500 Biosystems Applied

Systema PCR Temporis Realis Celeris Applied Biosystems 7500

QuantStudio®Quinque Systemata PCR Temporis Realis

Systema PCR Temporis Realis SLAN-96P

Cyclus Lucis®Systema PCR in Tempore Reali 480

Systema Detectionis PCR in Tempore Reali LineGene 9600 Plus

MA-6000 Cyclator Thermalis Quantitativus Temporis Realis

Systema PCR Temporis Realis BioRad CFX96

Systema PCR Temporis Realis BioRad CFX Opus 96

Fluxus Operis

Instrumentum Generale Macro & Micro-Test DNA/RNA (HWTS-3019) (quod cum Extractore Automatico Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B) adhiberi potest) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Adde 200µL...physiologicusSolutionem salinam ad praecipitatum processum adde, et gradus subsequentes secundum instructiones peragendi sunt. Volumen elutionis commendatum est 100 µL.


  • Praecedens:
  • Deinde:

  • Nuntium tuum hic scribe et nobis mitte.