19 Genera Sanguinis Infectio Pathogens

Description:

Ornamentum qualitative deprehendendi Pseudomonas aeruginosa (PA), Acinetobacter baumannii (ABA), Klebsiella pneumoniae (KPN), Escherichia coli (ECO), Staphylococcus aureus (SA), Enterobacter cloacae (ENC), Staphylococcus epidermidis

(STAE), Candida tropicalis (CTR), Candida krusei (CKR), Candida albicans (CA), Klebsiella

oxytoca (KLO), Serratia marcescens (SMS), Proteus mirabilis (PM), Streptococcus

pneumoniae (SP), Enterococcus faecalis (ENF), Enterococcus faecium (EFS), Candida

parapsilosis (CPA), Candida glabrata (CG) et Group B Streptococci (GBS) acida nucleica in speciminibus totius sanguinis.


Product Detail

Product Tags

Product nomen

HWTS-RT114A 19 Genera Sanguinis Infectio Pathogens Acidum nuclei Detection Ornamentum (Curva liquescens)

Testimonium

CE

Epidemiologia

Infectio sanguinis (BSI) est una ex morbis infectivis gravibus amet.Secundum varia symptomata, in sepsis, sepsis et septic offensio dividi potest[1-3].Infectio sanguinis causatur per bacteria pathogenicam systematis sanguinis invadendi, crescendi et multiplicandi in sanguine, multa toxinorum producentium et postea causando infectionem systemicam acutam cum morbiditate et mortalitate magna.Infectio communis fontes bacteria et fungos includunt.

Channel

通道 名称

PER-MIX 1

PER-MIX 2

FAM

PM.KPN

GBS.PA.ECO

HEX

CTR.CG.ENC.CA

ABA.Internum Imperium.SP

CY5

CKR.SMS

SA.KLO.STAE

ROX

EFS.Internum Imperium

CPA.ENF

Technical Parameters

Repono

≤-18℃

Fasciae vita XII mensibus
Specimen Type EDTA anticoagularis sanguinis
LoD SARS-CoV-2 erat 300 Copies/mL, influenza B virus erat 500 Copies/mL, influenza Virus erat 500 Copies/mL, adenovirus erat 500 Copies/mL, mycoplasma pneumoniae erat 500 Copies/mL, virus syncytiale respiratorium erat 500 Copies. /mL, parainfluenza virus (, , , erat 500 Copies/mL, chlamydia pneumoniae erat 500 Copies/mL, metapneumovirus humanus erat 500 Copies/mL, legionella pneumophila erat 1000/mL, streptococcus pneumoniae erat 1000/mL, staphylococcus aureus erat 5000/mL, pseudomonas aeruginosa erat 5000/mL. , klebsiella pneumoniae erat 1000/mL, haemophilus influenzae erat 1000/mL, acinetobacter oeni erat 1000/mL.
Specification Nulla transversalis actio est inter Streptococcum mutus, Streptococcus pyogenes, Haemophilus influenzae, Listeria monocytogenes, Neisseria meningitidis, Micrococcus luteus, Rhodococcus equi, Listeria gasseri, Acinetobacter gelata, Haemophilus parainfluenza, Neisseria sicca, Pseudomonas fluorescens, Candidasca. Legionella pneumophila, quae sunt extra probationem teli detectionis ornamentum.
Applicabilis Instrumenta SLAN-96P Real-time PCR Systems (Shanghai Hongshi Medical Technology Co., Ltd.)

Opus O


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis