Adenovirus Universal
Product nomen
HWTS-RT017A Adenovirus Universalis Nucleic Acidum Detection Kit (Fluorescens PCR)
Epidemiologia
Humanum adenovirus (HAdV) ad genus Mammalianum adenovirus pertinet, quod duplex virus sine involucro DNA subductis est.Adenoviri qui hucusque inventi sunt 7 subgroups (AG) et 67 species comprehendunt, e quibus 55 serotypa pathogenica sunt hominibus.Inter eos, ducens ad infectiones tractus tractus respiratorii maxime sunt coetus B (Type 3, 7, 11, 14, 16, 21, 50, 55), Group C (Type 1, 2, 5, 6, 57) et Group E (Typus 4), et infectio intestinorum diarrhoea ducens est F Group (Type 40 et 41) [1-8].Variae species symptomata orci diversa habent, sed praecipue infectiones tractus respiratorii.Morbi respiratorii tractus respiratorii causantur infectiones corporis humani propter 5%~15% morborum respiratorii globalis, et 5%-7% morborum respiratorii globalis infantiae[9].Adenovirus est endemicus in amplis locis et per totum annum infici potest, praesertim in frequentibus locis, quae ad tumultus locales, praesertim in scholis et castris militaribus, infici possunt.
Channel
FAM | adenovirus universalnucleicum acidum |
ROX | Internum Imperium |
Technical Parameters
Repono | ≤-18℃ |
Fasciae vita | XII mensibus |
Specimen Type | Nasopharyngeal swab.faucium swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 300Copie/mL |
Specification | a) Probare normas societatis notas negativas per ornamentum, et eventus experimentum requisitis occurrit. b) Hoc ornamento utere ad detegendam et transversim reactivitatem cum aliis pathogenis respiratoriis (ut Influenza A virus, Influenza B virus, virus syncytiale respiratorium, virus Parainfluenza, Rhinovirus, metapneumovirus Humani, etc.) vel bacteria (Streptococcus pneumoniae; Klebsiella pneumoniae, Pseudomonas aeruginosa, Acinetobacter oeni, Staphylococcus aureus, etc.). |
Applicabilis Instrumenta | Acta Biosystems (VII)D Real-time PCR Systems Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-time PCR Systems (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Real-time PCR systema LineGene 9600 Plus Real-time PCR Detection Systems (FQD-96A, HangzhouBioer technologia) MA-6000 Real-time Quantitatis Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-time PCR Systems, BioRad CFX Opus 96 Real-time PCR Systems |
Opus O
(1) Extraction commendatur iodo:Macro & Micro-Test Sample Release Reagent (HWTS-3005-8).Extractio facienda secundum mandatum.Extractum specimen est aegris'swab nasopharyngeal sive faucium swab exempla collecta in locum.Exempla in exemplum emissionis reagenti per Jiangsu Macro & Micro-test Med-Tech Co, Ltd., vortex bene misce, ad locus temperaturas 5 minutas pone, excipe et inverte et misce bene ad DNA obtinendum. quisque sample.
(2) Extraction commendatur iodo;Macro & Micro-Test Viral DNA/RNA Kit(HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) et Macro & Micro-test Automatic Extractor Nucleici Acidi (HWTS-3006C, HWTS-3006B).operatio stricte ex praecepto facienda est.Extractum specimen volumen est 200μL, etcommendatur elution volumineis80μL.
(III) commendatur extractionem reagens: Nucleic Acidum extractionem seu Purificationem Reagent (YDP315Tiangen Biotech (Beijing) Co.,Ltd., theoperatio stricte ex praecepto facienda est.Extractum specimen volumen est 200μL, etcommendatur elution volumineis80μL.