Chlamydia Trachomatis, Neisseria Gonorrhoeae et Trichomonas vaginalis
Product nomen
HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae et Trichomonas vaginalis Nuclei Acidum Detection Kit (Fluorescens PCR)
Epidemiologia
Chlamydia trachomatis (CT) est genus microorganismi prokaryotici quod proprie parasiticum in cellulis eukaryoticis est.Chlamydia trachomatis in AK serotypa secundum modum serotypi dividitur.Infectiones tractus urogenitalis plerumque causantur ex trachomate biologico DK serotypes variantium, et mares plerumque ut urethritis manifestantur, quae sine curatione levari possunt, sed pleraeque inveteratae, periodice aggravatae sunt, et componi possunt cum epididymitis, proctitis, etc.
Channel
FAM | Chlamydia trachomatis |
ROX | Neisseria gonorrhoeae |
CY5 | Trichomonales vaginae |
VIC/HEX | Internum Imperium |
Technical Parameters
Repono | -18℃ |
Fasciae vita | XII mensibus |
Specimen Type | Cervical femina swab,vaginalis femina swab,Swab urethrae masculinum |
Ct | ≤38 |
CV | <5% |
LoD | 400Codices / mL |
Specification | Nulla crux reactivitas cum aliis STD infectio pathogens extra detectionem range test ornamenti est, ut Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, etc. |
Applicabilis Instrumenta | Acta Biosystems (VII)D Real-time PCR System Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems QuantStudio®5 Real-time PCR Systems SLAN-96P Real-time PCR Systems LightCycler®480 Real-time PCR system LineGene 9600 Plus Real-time PCR Detection System MA-6000 Real-time Quantitatis Thermal Cycler BioRad CFX96 Real-time PCR System BioRad CFX Opus 96 Real-time PCR System |
Opus O
Optio 1 .
Commendatur extractio reagens: Pipette 1mL specimen probandi ad 1.5mL tubi centrifugii DNase/RNase, centrifugium ad 12000rpm per 3 minuta, supernatantem abiicias et praecipitatum serva.200µL salinarum normalium ad resuspendium praecipites adde.Macro & Micro-teste Generalis DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (quod adhiberi potest cum Macrone & Micro-test Automatico Acido Nucleico Extractor (HWTS-3006C, HWTS-3006B)) Jiangsu Macro & Micro-test Med-Tech Co., Ltd. extractio facienda est secundum instructionem ad usum.Extractum volumen specimen est 200µL, et volumen commendabile est 80µL.
Optio II.
Commendatur extraction reagens: Acidum nuclei extractionis vel Purificationis Kit (YDP302).Extractio stricte facienda est secundum instructionem ad usum.Volumen suadet elutionis 80µL.