Virus Multiplex, Zika Virus et Chikungunya Virus Multiplex
Product nomen
HWTS-FE040 Dengue Virus, Zika Virus et Chikungunya Virus Multiplex Nuclei Acidum Detection Kit (Fluorescens PCR)
Epidemiologia
Febris dengue (DF), quae infectio virus dengue (DENV) inducitur, est una ex morbis contagiosis arbovirus pestilentiae maxime.Media transmissio eius includit Aedes aegypti et Aedes albopictus.DF in locis tropicis et subtropicis maxime viget.DENV ad flaviviros flaviviridas pertinet, et in 4 serotypes secundum superficies antigenis indicari potest.Fuscus manifestationes DENV contagio maxime includunt capitis, febris, infirmitas, dilatatio nodi lymphae, leukopenia et cetera, et sanguinis, concussio, iniuria hepatica vel etiam mors in gravibus casibus.Superioribus annis, mutatio climatis, urbanizationis, celeris progressionis similesve et aliorum factorum condiciones celeriores et commodiores DF tradendi et divulgandi praebuerunt, ad constantem expansionem areae epidemicae DF.
Channel
FAM | MP Acidi nuclei |
ROX | Internum Imperium |
Technical Parameters
Repono | -18℃ |
Fasciae vita | IX mensibus |
Specimen Type | Nova serum |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 500 Copia/mL |
Specification | Interventus test eventus ostendunt, cum intentio bilirubin in serum non plus quam 168.2μmol/ml est, hemoglobinum concentratio ab hemolysin producta non plus quam 130g/L, remissio sanguinis lipidorum non plus quam 65mmol/ml est, tota Igg. intentio in serum non plus quam 5mg/mL, nulla effectus in virus dengue, virus Zika vel chikungunya deprehensio.Virus Hepatitis A, Hepatitis B virus, Hepatitis C virus, Virus Herpes, Virus equini Orientalis, virus encephalitis, Hantavirus, virus Bunya, virus Nili occidentale et exempla serum genomicorum hominum delecti sunt ad experimentum crucis-reactivitatis, et eventus ostendunt nullum esse. crucis reactionem inter hoc ornamentum et pathogen, de quibus supra. |
Applicabilis Instrumenta | Acta Biosystems (VII)D Real-time PCR System Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-time PCR Systems LightCycler®480 Real-time PCR systema LineGene 9600 Plus Real-time PCR Detection System MA-6000 Real-time Quantitatis Thermal Cycler BioRad CFX96 Real-time PCR System BioRad CFX Opus 96 Real-time PCR System |
Opus O
Optio 1 .
TIANamp Virus DNA/RNA Kit (YDP315-R), et extractio stricte agetur secundum instructionem ad usum.Extractum specimen voluminis 140μL est, et volumen commendabile est 60μL.
Optio II.
Macro & Micro-teste Generalis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (quod adhiberi potest cum Macrone & Micro-test Automatico Acido Nucleico Extractor (HWTS-3006C, HWTS-3006B)) Jiangsu Macro & Micro-test Med-Tech Co., Ltd., et extractio secundum instructionem ad usum facienda.Extractum specimen voluminis 200μL est, et volumen commendabile 80μL est.