Dengue virus, Zika virus et Chikungunya virus multiplex

Short description:

Hoc ornamentum est usus pro qualita deprehensio Dengue virus, Zika virus et Chikungunya virus nucleic acida in serum samples.


Product Detail

Product Tags

Product Name

HWTS, Fe040 Dengue virus, Zika virus et Chikungunya virus multiplex nucleic acidum deprehendatur Kit (Fluorence PCR)

Epidemiology

Dengue febricitantem (DF), quod inducitur per Dengue virus (DENV) infectio, est unus ex maxime pestilentia Arbovirus infectiones morbis. Et transmissione medium includit Aedes aegypti et aedes albictus. DF est maxime prevalent in tropicae et subtropical areas. Denv pertinet ad flavivirus sub Flaviviridae, et potest classificatis in IV serotypes secundum superficiem antigen. Volume manifestationes Denv infectio maxime includit capitis, febricitantem, debilitatem, dilatationem Lympha nodi, leukopenia etc. et cruentaque, inpulsa casibus. In annis, climate mutatio, Urbanization, velox progressionem voluptuaria similesve et aliis factoribus provisum est magis celeri et convenient condiciones ad transmittendi et expandit de DF, ducens ad constantium expansionem area DF.

Channel

Fam Denv nucleic acidum
ROX

Internum

Technical parametri

Repono

-18 ℃

PLUTEUM-vitae IX menses
Specimen Type Recens Serum
Ct ≤38
CV <5%
LOD D copies / ml
Specifica Intercessiones test eventus ostendere quod cum concentration of Bilirubin in Serum est non plus quam 168.2μmol / ml, in hemoglobin concentration produci per hemolysis non magis quam 130g / l, sanguis lipid non plus quam 130g / l, sanguis lipid non magis quam 65mmol / ml, totalis IGG Concentration in Serum non plus quam 5mg / ml, non est effectus in Dengue virus, Zika Virus aut Chikungunya virus deprehensio. Hepatitis virus, Hepatitis b virus, Hepatitis c virus, Herpesvirus virus, Orientis Equine ENCephalitis Virus, Humanum genomic Serum exemplaria sunt, quod non est Cross reactionem inter hoc ornamentum et pathogens de quibus supra.
COMPRESSUS Applicari Biosystems (VII) D Real-vicis PCR ratio

Applicari Biosystems (VII) D ieiunium realis-vicis PCR systems

Quantstudio®V Real-vicis PCR Systems

LightCycler®CDLXXX realis-vicis PCR ratio

Linenene (IX) DC plus realis-vicis PCR deprehensio ratio

MA-(VI) Real-vicis quantitatis scelerisque cycler

BIOD CFX96 Real-vicis PCR ratio

BIOD CFX Opus XCVI Real-vicis PCR ratio

ADMODO

Optio I.

Tianamp virus DNA / RNA Kit (YDP315-R) et extraction debet esse conducted in stricto secundum disciplinam ad usum. Extractum sample volumine est 140μl, et commendatur amet volumine 60μl.

Optio II.

Macro & Micro-test Generalis DNA / RNA Kit (HWTS-3017-50, HWTS, 3017-32, HWTS, 3017-48, HWTS, 3017-96) (quae potest esse cum Macro & Micro-test autum (HWTs, 3006c, HWTS, 3006b)) by Jiangsu Macro & Micro-test med-tech Co., Ltd. et extractionem debet esse secundum disciplinam ad usum. Et extractum sample volumine 200μl et commendatur Electio volumine 80μl.


  • Previous:
  • Next:

  • Scribere nuntium hic mitte nobis