Virus Hepatitis A
Nomen producti
HWTS-HP005 Instrumentum Detectionis Acidi Nucleici Virus Hepatitis A (PCR Fluorescens)
Epidemiologia
Virus hepatitidis A (HAV) causa principalis hepatitidis viralis acutae est. Virus est virus RNA monocatenarium positivo sensu et ad genus Hepadnavirus familiae Picornaviridae pertinet. Virus hepatitidis A, praecipue per viam faecalem-oralem transmittitur, calori, acidis, et plerisque solventibus organicis resistens, diu in conchis, aqua, solo, vel sedimentis fundi marini superesse potest [1-3]. Transmittitur per cibum vel aquam contaminatam, vel directe ab homine ad hominem transmittitur. Cibi cum HAV consociati includunt ostrea et conchae, fragae, rubi idaei, vaccinia, dactyli, olera foliosa viridia, et lycopersica semi-sicca [4-6].
Canalis
FAM | Acidum nucleicum HAV |
ROX | Imperium Internum |
Parametri Technici
Repositorium | ≤-18℃ |
Tempus conservationis | Liquidum: 9 menses, Lyophilizatum: 12 menses |
Typus Speciminis | Serum/alvus |
Tt | ≤38 |
CV | ≤5.0% |
Limitatio Detectionis (vel Limitatio Detectionis) | Duo exemplaria/μL |
Specificitas | Instrumentis utere ad alia virus hepatitidis examinanda, ut hepatitidem B, C, D, E, enterovirus 71, virus Coxsackie, virus Epstein-Barr, norovirus, HIV et genomum humanum. Nulla reactio transversalis est. |
Instrumenta Applicabilia | Systema PCR Temporis Realis Applied Biosystems 7500 Systema PCR Temporis Realis Celeris Applied Biosystems 7500 QuantStudio®Quinque Systemata PCR Temporis Realis SLAN-96P Systema PCR Temporis Realis (Societas Technologiae Medicae Hongshi, Ltd.) Systema PCR in Tempore Reali LightCycler®480 Systema Detectionis PCR in Tempore Reali LineGene 9600 Plus (FQD-96A, technologia Hangzhou Bioer), Cyclator Thermalis Quantitativus in Tempore Reali MA-6000 Systema PCR Temporis Realis BioRad CFX96 Systema PCR Temporis Realis BioRad CFX Opus 96 |
Fluxus Operis
Exempla seri
Optio 1.
Instrumentum Generale Macro & Micro-Test DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) et Extractor Automaticus Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B). Secundum instructiones extrahi debet. Volumen elutionis commendatum est 80µL.
Optio II.
Instrumentum TIANamp ad DNA/RNA Virus examinandum (YDP315-R), fabricatum a societate Tiangen Biotech (Beijing) Co., Ltd. Secundum instructiones extrahi debet. Volumen exempli extracti est 140μL. Volumen elutionis commendatum est 60µL.
2.Exempla Faecum
Instrumentum Generale Macro & Micro-Test DNA/RNA (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) et Extractor Automaticus Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B). Secundum instructiones extrahi debet. Volumen elutionis commendatum est 80µL.