Hepatitis A Virus

Description:

Hoc ornamentum aptum ad qualitatem detectionis hepatitis Virus (HAV) nucleici acidum in serum exempla et scabellum exempla in vitro.


Product Detail

Product Tags

Product nomen

HWTS-HP005 Hepatitis A Virus Nucleic Acidum Detection Kit (Fluorescens PCR)

Epidemiologia

Hepatitis Virus (HAV) est principalis causa hepatitis viralis acuti.Virus positivum sensu RNA virus uno-subductis est et ad genus Hepadnavirorum familiae Picornaviridae pertinet.Virus Hepatitis, a via fecal-oriali maxime traductum, calori, acida, et menstrua maxime organica renitens, diu superesse potest in conchis, aqua, solo, vel faeces maritato[1-3].Traditur per contaminationem cibi vel aquae vel ab homine directo traducitur.Victus cum HAV adiuncti sunt ostreis et clamis, fraga, raspberries, vaccinia, palmulae viridis herbae frondeae et lycopersica semiarida.

Channel

FAM HAV nucleicum acidum
ROX

Internum Imperium

Technical Parameters

Repono

≤-18℃

Fasciae vita Liquid: 9 menses, Lyophilized: 12 months
Specimen Type Serum/stella
Tt ≤38
CV ≤5.0%
LoD 2 Copia/μL
Specification Utere kits ad experimentum aliorum virus hepatitis ut hepatitis B, C, D, E, virus enterovirus 71, virus coxsackie, virus Epstein-Barr, norovirus, HIV et genome hominum. Nulla crux reactivitas est.
Applicabilis Instrumenta Acta Biosystems (VII)D Real-time PCR System

Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems

QuantStudio®5 Real-time PCR Systems

SLAN-96P Real-time PCR Systems (Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Real-time PCR systema

LineGene 9600 Plus Verus Tempus PCR Detection System (FQD-96A, Hangzhou Bioer technology), MA-6000 Real-time quantitatis Thermal Cycler

BioRad CFX96 Real-time PCR System

BioRad CFX Opus 96 Real-time PCR System

Opus O

Serum exempla

Optio 1 .

Macro & Micro-test Generalis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) et Macro & Micro-test Automatic Acidum Nucleicum Extractor (HWTS-3006C; HWTS-3006B).Extrahenda sunt secundum mandatum.Volumen suadet elutionis 80µL.

Optio II.

TIANamp Virus DNA/RNA Kit (YDP315-R) fabricatum a Tiangen Biotech (Beijing) Co., Ltd. extrahi debet secundum mandatum.Extractum specimen voluminis 140μL est.Volumen commendatur elutionis 60µL.

2.Sella Exempla

Macro & Micro-test Generalis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) et Macro & Micro-test Automatic Acidum Nucleicum Extractor (HWTS-3006C; HWTS-3006B).Extrahenda sunt secundum mandatum.Volumen suadet elutionis 80µL.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis

    Products categories