Virus Herpes Simplex Typus 1

Descriptio Brevis:

Hoc instrumentum ad detectionem qualitativam Virus Herpes Simplex Typi 1 (HSV1) adhibetur.


Detalia Producti

Etiquettae Productarum

Nomen producti

HWTS-UR006 Instrumentum Detectionis Acidi Nucleici Virus Herpes Simplex Typus 1 (PCR Fluorescens)

Epidemiologia

Morbi venerei (MST) adhuc inter gravissimas minas salutis publicae globalis numerantur, quae ad sterilitatem, partum praematurum, tumores et varias complicationes graves ducere possunt.[3-6]. STD pathogenum plura genera sunt, cum bacteria, virus, chlamydia, mycoplasma et spirochetae. Communes species sunt neisseria gonorrhoeae, mycoplasma genitalium, chlamydia trachomatis, herpes simplex virus type 1, herpes simplex virus type 2, mycoplasma hominis, ureaplasma urealyticum, etc.

Canalis

FAM Virus Herpes Simplex Typus 1 (HSV1)
ROX

Imperium Internum

Parametri Technici

Repositorium

-18℃

Tempus conservationis Duodecim menses
Typus Speciminis Peniculus cervical femininusPeniculus urethralis masculinus
Ct ≤38
CV ≤5.0%
Limitatio Detectionis (vel Limitatio Detectionis) quingentiExemplaria/mL
Specificitas Test alia STD infectio pathogens, ut treponema pallidum, chlamydia trachomatis, neisseria gonorrhoeae, mycoplasma hominis, mycoplasma genitalium, ureaplasma urealyticum, etc., nulla crux est reactio.
Instrumenta Applicabilia Systema PCR Temporis Realis 7500 Biosystems Applied

Systema PCR Temporis Realis Celeris Applied Biosystems 7500

QuantStudio®Quinque Systemata PCR Temporis Realis

Systema PCR Temporis Realis SLAN-96P

Cyclus Lucis®Systema PCR in Tempore Reali 480

Systema Detectionis PCR in Tempore Reali LineGene 9600 Plus

MA-6000 Cyclator Thermalis Quantitativus Temporis Realis

Systema PCR Temporis Realis BioRad CFX96

Systema PCR Temporis Realis BioRad CFX Opus 96

Fluxus Operis

Optio 1.

Reagentum ad Exempla Macro et Micro-Probanda Liberanda (HWTS-3005-8), extractio secundum IFU stricte peragenda est.

Optio II.

Instrumentum Generale Macro & Micro-Test DNA/RNA (HWTS-3017) et Extractor Automaticus Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B). Extractio secundum instructiones (IFU) peragenda est, et volumen elutionis commendatum est 80μL.

Optio III.

Reagens Extractionis vel Purificationis Acidi Nucleici (YDP302) a Tiangen Biotech (Beijing) Co., Ltd. Extractio stricte secundum IFU peragenda est, et volumen elutionis commendatum est 80μL.
Exempla DNA extracta statim examinanda sunt aut infra -18°C non plus quam septem menses conservanda. Numerus congelationis et liquefactionis repetitae quattuor cyclos non excedere debet.