HPV16 et HPV18'

Description:

Hoc ornamentum est intended pro in vitro qualitative detectionis acidi nucleici specificarum fragmentorum papillomavirorum humanorum (HPV) 16 et HPV18 in cellulis cervicali feminae exfoliatis.


Product Detail

Product Tags

Product nomen

HWTS-CC001-HPV16 et HPV18 Acidum Nucleicum Detection Ornamentum (Fluorescens PCR)

Epidemiologia

Cancer cervicus est unus e communissimis tumoribus malignis in tractu generationis feminae.Ostensum est infectio persistentes HPV et plures contagiones esse unum ex causis maioribus cancri cervicali.In statu adhuc defectus curationum efficacium receptarum pro cancro ceruicis causato ab HPV.Ergo mane deprehensio et praeventionis infectio cervicis ab HPV factae claves sunt ad praeventioni carcinomatis cervicalis.Constitutio simplex, specifica et celeri diagnostica probationum pathogens magni momenti est pro diagnosi cancri cervicali clinici.

Channel

Channel Type
FAM HPV18
VIC/HEX HPV16
CY5

Internum Imperium

Technical Parameters

Repono

≤-18℃

Fasciae vita XII mensibus
Specimen Type ceruicis exfoliated cellula
Ct ≤28
CV ≤10.0%
LoD 500 Copia/mL
Specification Cum ornamentum ad specimina non specialia exploranda quae cum suis scutis transire possunt, omnes eventus negativi sunt, inclusa Ureaplasma urealyticum, Chlamydia trachomatis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Robigo, Gardnerella et aliae HPV species non obtectae. ornamentum a.
Applicabilis Instrumenta SLAN®-96P Real-time PCR SystemsActa Biosystems (VII)D Real-time PCR Systems

QuantStudio®5 Real-time PCR Systems

LightCycler®480 Real-time PCR system

LineGene 9600 Plus Verus-Tempus PCR Detection System (FQD-96A, Hangzhou Bioer technology)

MA-6000 Real-time Quantitatis Thermal Cycler.

Opus O

Option1.

Macro & Micro-test Sample Reagent Release (HWTS-3005-8), extrahi debet secundum mandatum.

Option2.

Macro & Micro-test Generalis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) et Macro & Micro-test Automatic Acidum Nucleicum Extractor (HWTS-3006B; HWTS-3006C), extrahi debet secundum mandatum.Extractum volumen specimen 200μL est, et volumen commendabile est 80µL.

Option3.

QIAamp DNA Mini Kit (51304) fabricatum per QIAGEN vel TIANamp Virus DNA/RNA Kit (YDP315) fabricatum a Tiangen Biotech (Beijing) Co., Ltd, extrahi debet stricte secundum mandatum.Extractum volumen specimen 200μL est, et volumen commendabile est 80µL.