Influenza A Virus Universalis/H1/H3
Product nomen
HWTS-RT012 Influenza A Virus Universalis/H1/H3 Acidum Nucleicum Multiplex Deprehensio Kit(Fluorescens PCR)
Epidemiologia
Mycoplasma pneumoniae (MP) minimum est microorganismus prokaryoticus cum cella structura et nulla paries cellae inter bacteria et virus.MP maxime causat infectiones tractus respiratorii in hominibus, praesertim in pueris et iuvenibus.MP causare potest Mycoplasma hominis pneumonia, tractus respiratorii infectiones in pueris et pneumonia atypica.Signa clinica diversa sunt, plerumque tussis gravis, febris, infrigidatio, capitis faucium, tractus respiratorii superioris infectio et bronchopneumonia frequentissima sunt.Nonnulli aegroti graves peripleumonia ex contagione tractus respiratorii superioris, et angustia respiratoriae graves vel etiam mors evenire possunt.MP est una e communibus et magnis pathogenis in communitate peripneumonia quaesita (CAP), ratio pro 10%-30% cap, et proportio 3-5 vicibus augeri potest cum MP praevalet.Nuper, proportio MP in CAP pathogens paulatim aucta est.Incidentia Mycoplasma pneumoniae infectio aucta est, et propter eius manifestationes non specificas clinicae facile confundi cum frigoribus bacterial et viralibus.Ergo mane detectio laboratorium magni momenti est pro diagnosi et curatione clinica.
Channel
FAM | influenza Universale genus virus acidi nuclei |
VIC/HEX | influenza A H1 type virus acidi nuclei |
ROX | influenza A H3 type virus acidi nuclei |
CY5 | internum imperium |
Technical Parameters
Repono | ≤-18℃ |
Fasciae vita | IX mensibus |
Specimen Type | nasopharyngeal swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 500 Copia/μL |
Specification | Nulla crux-reactividad cum aliis speciminibus respiratoriis ut Influenza A, Influenza B, Legionella pneumophila, Rickettsia Q febris, Chlamydia pneumoniae, Adenovirus, Virus syncytialis respiratorii, Parainfluenza 1, 2, 3, virus Coxsackie, virus Echo, Metapneumovirus A1/A2/ B1/B2, Virus syncytialis respiratorii A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Virus Boca 1/2/3/4, Chlamydia trachomatis, adenovirus, etc. et genomicum humanum DNA. |
Applicabilis Instrumenta | Acta Biosystems (VII)D Real-time PCR System Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-time PCR Systems (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Real-time PCR systema LineGene 9600 Plus Verus-Tempus PCR Detection System (FQD-96A, Hangzhou Bioer technology) MA-6000 Real-time Quantitatis Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-time PCR System BioRad CFX Opus 96 Real-time PCR System |
Opus O
Nuclei Acidum extractionis seu Purificationis Reagenti (YDP315-R) auctore Tiangen Biotech (Beijing) Co.,Ltd.Extractio stricte exercenda est secundum instructiones ad usum.Extractum specimen voluminis 140μL est, et volumen commendabile est 60μL.
Optio II.