Hoc ornamentum in vitro qualitative detectionis Klebsiella pneumoniae (KPN), Acinetobacter baumannii (Aba), Pseudomonas aeruginosa (PA) et quattuor genes carbapenis resistentiae (in quibus KPC, NDM, OXA48 et IMP) includuntur, in sputo humano specimina praebent. fundamentum directionis diagnosis clinicae, curationum et medicamentorum cum suspecta contagione bacterial.


Product Detail

Product Tags

Product nomen

HWTS-RT109 Klebsiella Pneumoniae, Acinetobacter Baumannii et Pseudomonas Aeruginosa et Drug resistentia Genes (KPC, NDM, OXA48 et IMP) Multiplex detectio Ornamentum (Fluorescens PCR)

Testimonium

CE

Epidemiologia

Klebsiella pneumoniae communis est pathogenium clinicum opportunisticum et una ex bacteria pathogenica magni momenti infectiones nosocomiales causantes.Cum resistentia corporis reducta est, bacteria pulmonem intrant ex tractu respiratorii, infectionem causando in pluribus partibus corporis, et usus primus antibioticorum est clavis ad sanandum.[1].

Frequentissima situs baumannii Acinetobacteri infectio est pulmonis, qui est momenti pathogen pro Hospitalis pneumonia acquisita (HAP), praesertim Ventilator pneumonia consociata (VAP).Saepe comitatur cum aliis infectionibus bacterial et fungal, cum notis gravissimae morbiditatis rate et altae mortalitatis.

Pseudomonas aeruginosa frequentissima est bacilli in praxi clinico non-fermentative gram-negativa, et est magna opportunistica pathogen pro infectio hospitalis acquisita, cum characteribus faciles coloniationis, faciles variationis et multi-medici resistentiae.

Channel

Nomen PER-MIX 1 PER-MIX 2
FAM Channel Aba IMP
VIC/HEX Channel Internum Imperium KPC
CY5 Channel PA NDM
ROX Channel KPN OXA48

Technical Parameters

Repono

≤-18℃

Fasciae vita XII mensibus
Specimen Type Sputum
Ct ≤36
CV ≤10.0%
LoD 1000 CFU/mL
Specification a) Expertus crucis-reactivitatis ostendit hoc ornamentum non habere reactivitatem crucis cum aliis pathogenis respiratoriis, ut Streptococcus pneumoniae, Neisseria meningitidis, Staphylococcus aureus, Klebsiella oxytoca, Haemophilus influenzae, Acinetobacter gelata, Acinetobacter hemolytica, Legionella pneumophila, Pseudo- colia. fluorescens, Candida albicans, Chlamydia pneumoniae, respiratorii Adenovirus, Enterococcus et sputum exemplaria sine scutis, etc.

b) Facultatem anti-impedimenti: Lego mucin, minocyclinum, gentamicin, clindamycin, imipenem, cefoperazonem, meropenem, hydrochloridem ciprofloxacin, levofloxacin, acidum clavulanicum et roxithromycin, etc. ad impedimentum experimentum, et eventus ostendunt impedimentum substantiarum supra dictarum. non impedit detectio Klebsiella pneumoniae, Acinetobacteri oeni, Pseudomonas aeruginosa et carbapenem resistentia genes KPC, NDM, OXA48 and IMP.

Applicabilis Instrumenta Acta Biosystems (VII)D Real-time PCR Systems

Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems

QuantStudio®5 Real-time PCR Systems

LightCycler®480 Real-time PCR system

LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Bioer technology)

MA-6000 Real-time Quantitatis Thermal Cycler (Suzhou Molarray Co., Ltd.)

BioRad CFX96 Real-time PCR System

BioRad CFX Opus 96 Real-time PCR System

Opus O

Summa PCR Solutio