MTHFR Gene Polymorphic Nucleic Acidum

Description:

Hoc ornamentum adhibetur ad deprehendendas 2 mutationis situs gene MTHFR.Ornamentum totius sanguinis humano utitur ut specimen exempli ad qualitatem status mutationis aestimationem praebendam.Clinicianis subvenire potest ad consilia curationis excogitandas pro diversis notis singularibus e gradu hypothetico aptas, ad salutem aegrotorum quam maxime fovendam.


Product Detail

Product Tags

Product nomen

HWTS-GE004-MTHFR Gene Polymorphic Nucleic Acidum Detection Ornamentum (ARMS-PCR)

Epidemiologia

Acidum folicum est vitaminum aquaticum solubile id est cofactor essentialis in metabolicis viae corporis.Annis ingentes studiorum numerus confirmaverunt mutationem folatium metabolizationis enzyme gene MTHFR ad defectum acidi folici in corpore deducendum, et damnum commune acidi folici defectus in adultis megaloblasticam anemiam, vascularem causare potest. damnum endotheliale etc. Folic acidum defectus in gravidis mulieribus non possunt occurrere necessitatibus sui et foetus, qui defectibus tubus neuralis, anencephalia, abortus et abortus causare possunt.Serum gradus folatium 510-methylenetetrahydrofolatum reductasi (MTHFR) polymorphismi afficiuntur.In 677C>T et 1298A>C mutationum generum MTHFR conversionem alaninarum ad acidum valine et glutamicum inducunt, respective, inde in activitatem MTHFR reductam ac proinde acidi folici utendo reduci.

Channel

FAM MTHFR C677T
ROX MTHFR A1298C
VIC(HEX) Internum imperium

Technical Parameters

Repono

≤-18℃

Fasciae vita

XII mensibus

Specimen Type

Nuper collecta EDTA anticoagulato sanguine

CV

≤5.0%

Ct

≤38

LoD

1.0ng/μL

Instrumenta applicabilia:

Acta Biosystems (VII)D Real-time PCR Systems

Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems

SLAN ®-96P Real-time PCR Systems

QuantStudio™ 5 Real-Time PCR Systems

LightCycler®480 Real-time PCR systema

LineGene 9600 Plus Real-time PCR Detection System

MA-6000 Real-time Quantitatis Thermal Cycler

BioRad CFX96 Real-time PCR System

BioRad CFX Opus 96 Real-time PCR System

Opus O

Optio 1

Commendatur extractio reagentium: Macro & Micro-test Genomic DNA Kit (HWTS-3014-32, HWTS-3014-48, HWTS-3014-96) et Macro & Micro-test Automatic Acidum Nucleicum Extractor (HWTS-3006C, HWTS-3006B) .

Optio 2

Commendatur extraction reagentia: Sanguinis Genomic DNA Extraction Kit (YDP348, JCXB20210062) Tiangen Biotech (Beijing) Co.,Ltd.Sanguinis Genome Extraction Ornamentum (A1120) by Promega.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis