Mycoplasma Pneumoniae (MP)
Product nomen
HWTS-RT024 Mycoplasma Pneumoniae(MP) Nucleicum Acidum Detection Ornamentum (Fluorescens PCR)
Epidemiologia
Mycoplasma pneumoniae (MP) est genus microorganismi minimi prokaryotici, qui est inter bacteria et virus, cum structura cellae sed nulla muri cellula.MP maxime causat infectionem tractus respiratorii humani, praesertim in pueris et iuvenibus.Mycoplasma pneumonia, tractus respiratorii infantum, infectionem et pneumoniam atypicam causare potest.Orci manifestationes variae sunt, quarum pleraeque sunt gravissima tussis, febris, frigora, capitis, faucium.Infectio tractus respiratorii superioris et pneumonia bronchiales frequentissima sunt.Nonnulli aegroti e tractus respiratorii superioris infectio ad gravem pneumoniam, gravem respiratoriam angustiam et mortem evolvere possunt.
Channel
FAM | Mycoplasma pneumoniae |
VIC/HEX | Internum Imperium |
Technical Parameters
Repono | ≤-18℃ |
Fasciae vita | XII mensibus |
Specimen Type | Sputum、Oropharyngeal swab |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 200 Copies/mL |
Specification | a) Crux reactivitas: nulla crux reactivatio cum Ureaplasma urealyticum, Mycoplasma genitalium, Mycoplasma hominis, Streptococcus pneumoniae, Chlamydia pneumoniae, Haemophilus influenzae, Klebsiella pneumoniae, Staphylococcus aureus, Mycobacterium tuberculosis, In aestivum baen virus. , Influenza B virus, Parainfluenza genus virus I/II/III/IV, Rhinovirus, Adenovirus, metapneumovirus humanus, virus syncytiale respiratorium et acidum genomicum nucleicum humanum. b)Anti-impedimenti facultatem: nihil impedimenti est cum substantiae impedimento probatae sunt his concentratione: haemoglobina (50mg/L), bilirubin (20mg/dL), mucin (60mg/mL), 10% (v/v) sanguis humanus, levofloxacin (10μg/mL), moxifloxacin(0.1g/L), gemifloxacin (80μg/mL), azithromycin (1mg/mL), clarithromycin (125μg/mL), erythromycinum (0.5g/L), doxycyclinum (50mg /L), minocycline (0.1g/L). |
Applicabilis Instrumenta | Acta Biosystems (VII)D Real-time PCR System Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems QuantStudio®5 Real-time PCR Systems SLAN-96P Real-time PCR Systems (Hongshi Medical Technology Co., Ltd.) LightCycler®480 Real-time PCR system LineGene 9600 Plus Verus-Tempus PCR Detection System (FQD-96A, Hangzhou Bioer technology) MA-6000 Real-time Quantitatis Thermal Cycler (Suzhou Molarray Co., Ltd.) BioRad CFX96 Real-time PCR System BioRad CFX Opus 96 Real-time PCR System |
Opus O
(1) Sputum Sample
Extraction reagens commendatur: Macro & Micro-test Viralis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (quae adhiberi possunt cum Macrone & Micro-Test. Automaticum Acidum Nucleicum Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-test Med-Tech Co., Ltd. 200µL adde salinum normalem in praecipiti processionaliter.Extractio sequens facienda est secundum instructionem ad usum.Volumen commendatur elutionis 80µL. Commendatur extractio reagens: Acidum nuclei extractio seu Purificatio Reagentis (YDP315-R).Extractio stricte facienda est secundum instructionem ad usum.Volumen commendatur elutionis 60µL.
(2) Oropharyngeal swab
Extraction reagens commendatur: Macro & Micro-test Viralis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (quae adhiberi possunt cum Macrone & Micro-Test. Automatic Acidum Nucleicum Extractor (HWTS-3006C, HWTS-3006B)) per Jiangsu Macro & Micro-test Med-Tech Co., Ltd. extractio facienda est secundum instructionem ad usum.Commendatum volumen extractionis specimen est 200µL, et commendatur elutio voluminis 80µL. Commendatur extractio reagens: QIAamp Viral RNA Mini Kit (52904) vel Acidum nuclei extractio seu Purificatio Reagenti (YDP315-R).Extractio stricte facienda est secundum instructionem ad usum.Voluminis extractio suadeo specimen est 140µL, et volumen commendationis elutionis est 60µL.