Novem Genera Virusorum Respiratoriorum
Nomen producti
HWTS-RT185A-Instrumentum Detectionis Acidi Nucleici Novem Generum Virusorum Respiratoriorum (PCR Fluorescens)
Epidemiologia
Infectio tractus respiratorii est genus morbi humani frequentissimum, quod in quolibet genere, aetate et regione occurrere potest, et una ex gravissimis causis morbiditatis et mortis in mundo est.[1]. Fuscum commune respiratorium pathogens includit influenza virus (IFV A), influenza B virus (IFV B), novum coronavirus (SARS-CoV-2), virus respiratorii syncytialis, adenovirus, metapneumovirus humanus, rhinovirus, virus parainfluenza (I/II/III), et mycoplasma pneumoniae, etc.[2,3]Symptomata et signa clinica ab infectione tractus respiratorii effecta relative similia sunt, sed infectio a variis pathogenis effecta varias curationes, effectus curativos et cursum morbi habet.[4,5]In praesenti, principales methodi detectionis laboratorio pathogenorum respiratoriorum includunt: isolationem virus, detectionem antigeni et detectionem acidorum nucleicorum. Hoc instrumentum acida nucleica viralia specifica in individuis cum signis et symptomatibus infectionis respiratoriae detegit et identificat, una cum aliis resultatis clinicis et laboratorio ad auxilium in diagnosi infectionis viralis respiratoriae.
Canalis
FAM | Acidum nucleicum MP |
ROX | Imperium Internum |
Parametri Technici
Repositorium | 2-8℃ |
Tempus conservationis | Duodecim menses |
Typus Speciminis | Peniculus oropharyngeus; Peniculus nasopharyngeus |
Ct | COVID-9, IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35 |
CV | <5.0% |
Limitatio Detectionis (vel Limitatio Detectionis) | 200 Exemplaria/mL |
Specificitas | Reactio cruciata: Nulla reactio cruciata existit inter apparatum et virus Boca, Cytomegalovirus, virus Epstein-Barr, virus Herpes simplex, virus Varicellae zoster, virus Parotitis, Enterovirus, virus morbillorum, coronavirus humanum, coronavirus SARS, coronavirus MERS, Rotavirus, Norovirus, Chlamydia pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus influenzae, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tuberculosis, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivarius, Moraxella catarrh, Lactobacillum, Corynebacterium, DNA genomicum humanum. Examen interferentiae: Selecta mucinum (60mg/mL), sanguinem humanum (50%), benephrinum (2mg/mL), hydroxymethazolinum (2mg/mL) (2mg/mL), natrii chloridum cum 5% conservativo (20mg/mL), beclomethasonum (20mg/mL), dexamethasonum (20mg/mL), fluniacetonum (20μg/mL), triamcinolonum (2mg/mL), budesonidum (1mg/mL), mometasonum (2mg/mL), fluticasonum (2mg/mL), histamini hydrochloridum (5mg/mL), benzocainum (10%), mentholum (10%), zanamivirum (20mg/mL), peramivirum (1mg/mL), mupirocinum (20mg/mL), tobramycinum (0.6mg/mL), oseltamivirum (60ng/mL), ribavirinum (10mg/L). Resultata ostenderunt substantias interferentes in supradicta concentratione nullam reactionem interferentem ad detectionem apparati habuisse. |
Instrumenta Applicabilia | Reagenti detectionis typi I applicabile: Systemata PCR in Tempore Reali Applied Biosystems 7500, QuantStudio®Quinque Systemata PCR Temporis Realis, Systemata PCR Temporis Realis SLAN-96P (Hongshi Medical Technology Co., Ltd.), Systemata Detectionis PCR Temporis Realis LineGene 9600 Plus (FQD-96A, Hangzhou Bioer technology), Cyclator Thermalis Quantitativus Temporis Realis MA-6000 (Suzhou Molarray Co., Ltd.), Systema PCR Temporis Realis BioRad CFX96, Systema PCR Temporis Realis BioRad CFX Opus 96. Ad reagens detectionis typi II applicabile: Eudemon™ AIO800 (HWTS-EQ007) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Repositorium | 2-8℃ |
Tempus conservationis | Duodecim menses |
Typus Speciminis | Peniculus oropharyngeus; Peniculus nasopharyngeus |
Ct | COVID-9, IFV A, IFVB, RSV, Adv, hMPV, Rhv, PIV, MP Ct≤35 |
CV | <5.0% |
Limitatio Detectionis (vel Limitatio Detectionis) | 200 Exemplaria/mL |
Specificitas | Reactio cruciata: Nulla reactio cruciata existit inter apparatum et virus Boca, Cytomegalovirus, virus Epstein-Barr, virus Herpes simplex, virus Varicellae zoster, virus Parotitis, Enterovirus, virus morbillorum, coronavirus humanum, coronavirus SARS, coronavirus MERS, Rotavirus, Norovirus, Chlamydia pneumoniae, Streptococcus pneumoniae, Klebsiella pneumoniae, Streptococcus pyogenes, Legionella, Pneumospora, Haemophilus influenzae, Bacillus pertussis, Staphylococcus aureus, Mycobacterium tuberculosis, gonococcus, Candida albicans, Candida glabra, Aspergillus fumigatus, Cryptococcus neoformans, Streptococcus salivarius, Moraxella catarrh, Lactobacillum, Corynebacterium, DNA genomicum humanum. Examen interferentiae: Selecta mucinum (60mg/mL), sanguinem humanum (50%), benephrinum (2mg/mL), hydroxymethazolinum (2mg/mL) (2mg/mL), natrii chloridum cum 5% conservativo (20mg/mL), beclomethasonum (20mg/mL), dexamethasonum (20mg/mL), fluniacetonum (20μg/mL), triamcinolonum (2mg/mL), budesonidum (1mg/mL), mometasonum (2mg/mL), fluticasonum (2mg/mL), histamini hydrochloridum (5mg/mL), benzocainum (10%), mentholum (10%), zanamivirum (20mg/mL), peramivirum (1mg/mL), mupirocinum (20mg/mL), tobramycinum (0.6mg/mL), oseltamivirum (60ng/mL), ribavirinum (10mg/L). Resultata ostenderunt substantias interferentes in supradicta concentratione nullam reactionem interferentem ad detectionem apparati habuisse. |
Instrumenta Applicabilia | Reagenti detectionis typi I applicabile: Systemata PCR in Tempore Reali Applied Biosystems 7500, QuantStudio®Quinque Systemata PCR Temporis Realis, Systemata PCR Temporis Realis SLAN-96P (Hongshi Medical Technology Co., Ltd.), Systemata Detectionis PCR Temporis Realis LineGene 9600 Plus (FQD-96A, Hangzhou Bioer technology), Cyclator Thermalis Quantitativus Temporis Realis MA-6000 (Suzhou Molarray Co., Ltd.), Systema PCR Temporis Realis BioRad CFX96, Systema PCR Temporis Realis BioRad CFX Opus 96. Ad reagens detectionis typi II applicabile: Eudemon™ AIO800 (HWTS-EQ007) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Fluxus Operis
Instrumentum Macro & Micro-Test Viral DNA/RNA (HWTS-3017) (quod cum Extractore Automatico Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B) adhiberi potest), et Instrumentum Macro & Micro-Test Viral DNA/RNA (HWTS-3017-8) (quod cum Eudemon adhiberi potest).TM AIO800 (HWTS-EQ007)) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Volumen exempli extracti est 200 μL et volumen elutionis commendatum est 150 μL.