Zaire Ebola Virus

Description:

Hoc ornamentum aptum ad qualitatem detectionis viri Zaire Ebola acidum nucleicum in serum vel plasma exemplorum aegrorum suspectorum virus Zaire Ebola (ZEBOV) infectio.


Product Detail

Product Tags

Product nomen

HWTS-FE008 Zaire Ebola Virus Nucleic Acidum Detection Kit (Fluorescens PCR)

Epidemiologia

Virus Ebola ad Filoviridas pertinet, quod est virus RNA negativo-stratum insegmentosum.Virus filamenta longa sunt cum mediocris virionis longitudine 1000nm et diametro circiter 100nm.Virus Ebola genome insegmen-stratum negativum est RNA cum magnitudine 18.9kb, descriptam 7 servo structuris et dapibus non-structuralibus.Virus Ebola in genera dividi potest sicut Zaire, Sudan, Bundibugyo, Tai Silva et Reston.Inter eos, typus Zaire et genus Sudan delatae sunt causa multorum hominum ex contagione mortibus.EHF (febris Ebola hemorrhagia) est morbus acutus hemorrhagicus contagiosus per virus Ebola causatus.Homines maxime contactu inficiuntur cum humoribus, secretionibus et excretis aegrorum vel animalium infectis, ac manifestationes clinicae maxime prominentes febres, sanguinem sanguinis et damnum multiplex organi.EHF mortalitatis rate of 50%-90% habet.

Channel

FAM MP Acidi nuclei
ROX

Internum Imperium

Technical Parameters

Repono

≤-18℃

Fasciae vita IX mensibus
Specimen Type Nova serum、Plasma
Tt ≤38
CV ≤5.0%
LoD 500 Copia/μL
Specification Utere kits ad probationes societatis negativas, eventus metus.
Applicabilis Instrumenta Acta Biosystems (VII)D Real-time PCR Systems

Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems

QuantStudio®5 Real-Time PCR Systems

SLAN-96P Real-time PCR Systems (Hongshi Medical Technology Co., Ltd.)

LightCycler®480 Real-time PCR systema

LineGene 9600 Plus Verus-Tempus PCR Detection System(FQD-96A, Hangzhou Bioer technology)

MA-6000 Real-time Quantitatis Thermal Cycler (Suzhou Molarray Co., Ltd.)

BioRad CFX96 Real-Time PCR System, and BioRad CFX Opus 96 Real Time PCR System

Opus O

Optio 1 .

Commendatur extraction reagens: QIAamp Viral RNA Mini Kit (52904), Acidum Nucleicum Extraction seu Purificationis Reagenti (YDP315-R) Tiangen Biotech (Beijing) Co.,Ltd.Extrahi debet stricte ad normam praeceptorum, et extractio exemplaris commendaticii est 140μL, et commendatur elutionis volumen 60μL.

Optio II.

Extraction reagens commendatur: Macro & Micro-test Viralis DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) et Macro & Micro-test Automatic Extractor Nucleici Acidi (HWTS-3006). extrahi secundum mandatum.Extractio voluminis specimen 200μL est, et volumen commendabile 80μL est.

Optio III.

Commendatur extractio reagentium: Extractio Acidum nuclei Reagenti (000020261) et Praecipuum Systematis Praeparationis Sample Automated (MGISP-960) ab BGI extrahendum secundum instructiones.Extractio voluminis 160μL est, et volumen commendabile est 60μL.


  • Previous:
  • Deinde:

  • Epistulam tuam hic scribe et mitte nobis