XVII genera HPV (16/18/6/11/44 typing)
Product Name
HWTS-cc015 XVII genera humanae Papillomavirus (16/18/6/11/44 typing) Nucleic Acidum deprehendatur Kit (Fluorence PCR)
Epidemiology
Ceruicis cancer est maxime commune malignus tumores in femina generationis tractu. Hoc est ostensum est quod pertinax HPV infectio et multiple infectiones sunt unum de major causas ceruicis cancer. Currently est adhuc indigentiam plerumque accepit effective treatments pro ceruicis cancer per HPV. Ideo mane deprehendatur et praeventionis ceruicis infectio per HPV sunt claves ad praeventionis ceruicis cancerization. Stainment of simplex, specifica et celeri Diagnostic probat pro pathogens est magni momentum pro orci diagnosis de ceruicis cancer.
Channel
PCR-Mix1 | Fam | 18 |
Vic / Hex | 16 | |
ROX | 31,33,35,39,45,51,52,56,58,59,66,68 | |
CYV | Internum |
PCR Mix2 | Fam | 6 |
Vic / Hex | 11 | |
ROX | 44 | |
CYV | Internum |
Technical parametri
Repono | -18 ℃ |
PLUTEUM-vitae | XII mensibus |
Specimen Type | Urina Sample, Male Ceruicis Swab Sample, Male vaginal Swab sample |
Ct | ≤28 |
LOD | 300Copies / ml |
Specifica | Non est crucem-reactivity cum urallasma ulcere Tractus, Chlamydia Trachomatis de generatiua tractu, Candida Albicans, neisseria Gonorrhoeae, Trichomonas vaginalis, Fingunt, Gardnerella et alia HPV genera non operuit ornamentum. |
COMPRESSUS | Applicari Biosystems (VII) D Real-vicis PCR Systems Applicari Biosystems (VII) D ieiunium realis-vicis PCR systems Quantstudio®V Real-vicis PCR Systems Slan-96P realis-vicis PCR systems LightCycler®CDLXXX realis-vicis PCR systems Linenene (IX) DC plus realis-vicis PCR deprehendatur Systems MA-(VI) Real-vicis quantitatis scelerisque cycler BIOD CFX96 Real-vicis PCR ratio BIOD CFX Opus XCVI Real-vicis PCR ratio |
ADMODO
Commendatur extraction Reagent: Macro & Micro-test viral DNA / RNA Kit (HWTS, 3017-50, HWTS, 3017-32, HWTS, 3017-48, HWTS-3017-96) (qui possunt esse cum Macro & Micro-test esse cum Macro-3017-96, test Automatic Nucleic Acidum extractor (HWTS, 3006C, HWTS, 3006b)) by Jiangsu Macro & Micro-test med-tech Co., Ltd. Add 200μl normalis SAL ad resuspendant in pellem gradum 2.1 et extraction debet esse secundum instructiones ad usum huius extraction Reagent. Commendatur Electio volumine 80μl.
Commendatur extraction Reagent: Qiaamp DNA Mini Ornamentum ((LI) CCCIV) aut Macro & Micro-test viral DNA / RNA columnae (HWTS, 3020-50). Addere 200μl of normalis SAL ad resuspendant in step 2.1, tum extractionem debet esse secundum instructiones ad usum huius extraction Reagent. Extractum sample volumine ex exempla omnes 200μl et commendatur Electio volumine est 100μl.
Commendatur extraction Reagent: Macro & Micro-test sample dimittis Reagent (HWTS-3005-8i, HWTS, 3005-8J, HWTS, 3005-8K, HWTS, 3005-8L). Addere 200μl of sample dimittis Reagent ad resuspendant in pellem gradum 2.1, tum extractionem debet esse conducted secundum instructiones ad usum huius extraction Reagent.