17 Genera HPV (16/18/6/11/44 Typing)
Product nomen
HWTS-CC015 17 Papillomavirus Humani Genera (16/18/6/11/44 Typing) Acidi Nucleici Detection Ornamentum (Fluorescens PCR)
Epidemiologia
Cancer cervicus est unus e communissimis tumoribus malignis in tractu generationis feminae.Ostensum est infectio persistentes HPV et plures contagiones esse unum ex causis maioribus cancri cervicali.In statu adhuc defectus curationum efficacium receptarum pro cancro ceruicis causato ab HPV.Ergo mane deprehensio et praeventionis infectio cervicis ab HPV factae claves sunt ad praeventioni carcinomatis cervicalis.Constitutio simplex, specifica et celeri diagnostica probationum pathogens magni momenti est pro diagnosi cancri cervicali clinici.
Channel
Pcr-Mix1 | FAM | 18 |
VIC/HEX | 16 | |
ROX | 31,33,35,39,45,51,52,56,58,59,66,68 | |
CY5 | Internum imperium |
Pcr-Mix2 | FAM | 6 |
VIC/HEX | 11 | |
ROX | 44 | |
CY5 | Internum imperium |
Technical Parameters
Repono | -18℃ |
Fasciae vita | XII mensibus |
Specimen Type | Vrina specimen, swab ceruicis femina sample, femina vaginalis swab specimen |
Ct | ≤28 |
LoD | 300Copie/mL |
Specification | Nulla crux reactivatio cum Ureaplasma urealyticum, Chlamydia trachomatis tracti generationis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Molda, Gardnerella et aliae HPV species ornamento non obtectae. |
Applicabilis Instrumenta | Acta Biosystems (VII)D Real-time PCR Systems Acta Biosystems (VII)D Fast Verus-Tempus PCR Systems QuantStudio®5 Real-time PCR Systems SLAN-96P Real-time PCR Systems LightCycler®480 Real-time PCR Systems LineGene 9600 Plus Real-time PCR Detection Systems MA-6000 Real-time Quantitatis Thermal Cycler BioRad CFX96 Real-time PCR System BioRad CFX Opus 96 Real-time PCR System |
Opus O
Extraction reagens commendatur: Macro & Micro-test Viralis DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (quae adhiberi possunt cum Macrone & Micro-Test. Automatic Acidum Nucleicum Extractor (HWTS-3006C, HWTS-3006B)) per Jiangsu Macro & Micro-test Med-Tech Co., Ltd. 200μL addere salinarum normalium ad resuspendendum globulo in gradu 2.1, et tunc agendus est extractio secundum instructiones ad hanc extrahendam iodo.Voluminis evolutionis commendata 80μL est.
Commendatur extractio reagens: QIAamp DNA Mini Kit (51304) vel Macro & Micro-test Viralis DNA/RNA Columna (HWTS-3020-50).200μL addere salinarum normalium ad resuspendendas globulo in gradatim 2.1, tum extractio facienda est secundum instructiones ad usum huius extractionis iodi.Extractum specimen exemplarium sunt omnes 200μL, et volumen commendabile est 100μL.
Extraction reagens commendatur: Macro & Micro-test Sample Reagens (HWTS-3005-8I, HWTS-3005-8J, HWTS-3005-8K, HWTS-3005-8L).200μL addere specimen emissionis gerentis ad resuspendendum globulo in gressu 2.1, et deinde extractio secundum instructiones ad usum huius extractionis gerentis agetur.