Staphylococcus Aureus et Staphylococcus Aureus Methicillino Resistens (MRSA/SA)
Nomen producti
HWTS-OT062 Staphylococcus Aureus et Staphylococcus Aureus Methicillino Resistentis (MRSA/SA) Instrumentum Detectionis Acidi Nucleici (PCR Fluorescens)
Certificatum
CE
Epidemiologia
Staphylococcus aureus est una ex bacteriis pathogenicis magni momenti infectionis nosocomialis. Staphylococcus aureus (SA) ad staphylococcos pertinet et repraesentat bacteriis Gram-positivis, quae varietatem toxinorum et enzymorum invasivorum producere possunt. Bacteria habent proprietates distributionis latae, pathogenicitatis validae et resistentiae altae. Gen nucleasis thermostabilis (nuc) est gen Staphylococci aurei valde conservatum.
Canalis
FAM | gen mecA methicillino-resistens |
ROX | Imperium Internum |
CY5 | genum nuclei Staphylococci aurei |
Parametri Technici
Repositorium | ≤-18℃ et a luce protectum |
Tempus conservationis | Duodecim menses |
Typus Speciminis | Sputi, exempla infectionum cutis et textus mollis, et exempla penicilli nasalis |
Ct | ≤36 |
CV | ≤5.0% |
Limitatio Detectionis (vel Limitatio Detectionis) | 1000 CFU/mL Staphylococci aurei, 1000 CFU/mL bacteria methicillino resistentia. Cum instrumentum LoD nationalem detegit, 1000/mL Staphylococci aurei detegi potest. |
Specificitas | Examen reactionis cruciatae ostendit hoc instrumentum nullam reactionem cruciatam cum aliis pathogenis respiratoriis habere, ut Staphylococcus aureus methicillino-sensibilis, Staphylococcus coagulase-negativus, Staphylococcus epidermidis methicillino-resistens, Pseudomonas aeruginosa, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Proteus mirabilis, Enterobacter cloacae, Streptococcus pneumoniae, Enterococcus faecium, Candida albicans, Legionella pneumophila, Candida parapsilosis, Moraxella catarrhalis, Neisseria meningitidis, Haemophilus influenzae. |
Instrumenta Applicabilia | Systema PCR Temporis Realis 7500 Biosystems Applied QuantStudio®Quinque Systemata PCR Temporis Realis Systema PCR Temporis Realis SLAN-96P Cyclus Lucis®Systema PCR in Tempore Reali 480 Systema Detectionis PCR in Tempore Reali LineGene 9600 Plus MA-6000 Cyclator Thermalis Quantitativus Temporis Realis Systema PCR Temporis Realis BioRad CFX96 Systema PCR Temporis Realis BioRad CFX Opus 96 |
Fluxus Operis
Optio 1.
Instrumentum Macro & Micro-Test Genomic DNA/RNA (HWTS-3019) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. cum Extractore Automatico Acidi Nucleici Macro & Micro-Test (HWTS-3006C, HWTS-3006B) adhiberi potest. Adde 200µL solutionis salinae normalis praecipitato processato, et gradus subsequentes secundum instructiones extrahendi sunt, et volumen elutionis commendatum est 80µL.
Optio II.
Reagentum ad Exempla Macro & Micro-Test Liberanda (HWTS-3005-8) a Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Adde 1mL solutioni salinae normalis praecipitato post ablutionem solutione salina normali, deinde bene misce. Centrifuga ad 13,000r/min per 5 minuta, supernatans remove (serva 10-20µL supernatantis), et instructiones pro extractione subsequenti sequere.
Reagens extractionis commendatum: Reagens Extractionis vel Purificationis Acidi Nucleici (YDP302) a Tiangen Biotech (Beijing) Co., Ltd. Extractio stricte secundum gradum 2 manualis instructionum peragenda est. Aquam sine RNase et DNase ad elutionem cum volumine 100µL commendatur.