Zika virus
Product Name
HWTS-F002 Zika virus nucleic acidum deprehendatur Kit (Fluorence PCR)
Certificatorium
CE
Epidemiology
Zika virus pertinet ad genus Flaviviridae, est unum, subditos positivum-subdita RNA virus cum diameter 40-80nm. Habet involucro, continet (X) DCCXCIV nucleotides et encodes MMMCDXIX amino acida. Secundum ad genotype, quod dividitur in African genus et Asian genus. Zika virus morbo est a se-limitandi acuti infectiosis morbus causatur a Zika virus, quae est maxime traducitur per mordere Aedes aegypti culicibus. Et orci features sunt maxime febrem, temere, arthralgia et conjunctivitis, et raro exitiale. Secundum ad Mundi Salus Organization, neonatal microcephaly et Guillain-Barre syndrome (Guillain-Barré syndrome) potest esse consociata cum Zika virus infectio.
Channel
Fam | Zika virus nucleic acidum |
ROX | Internum |
Technical parametri
Repono | ≤30 ℃ & protected ex lux |
PLUTEUM-vitae | XII mensibus |
Specimen Type | recens Serum |
Ct | ≤38 |
CV | <5.0% |
LOD | 500copies / ml |
Specifica | Utere ad ornamentum ad deprehendere serum exempla cum Zika virus negans, et eventus sunt negans. Intercessiones test eventus ostendere quod cum concentration of Bilirubin in Serum est non plus quam 168.2μmol / ml, in hemoglobin concentration produci per hemolysis non magis quam 130g / l, sanguis lipid non plus quam 130g / l, sanguis lipid non magis quam 65mmol / ml, totalis IGG Concentration in Serum non plus quam 5mg / ml, non est effectus in Dengue virus, Zika Virus aut Chikungunya virus deprehensio. Hepatitis virus, Hepatitis b virus, Hepatitis c virus, Herpesvirus virus, Orientis Equine ENCephalitis Virus, Humanum genomic Serum exemplaria sunt, quod non est Cross reactionem inter hoc ornamentum et pathogens de quibus supra. |
COMPRESSUS | Abi (VII) D Verus-vicis PCR SystemsAbi (VII) D ieiunium realis-vicis PCR systems Quantstudio®V Real-vicis PCR Systems Slan-96P realis-vicis PCR systems LightCycler®CDLXXX realis-vicis PCR ratio Linenene (IX) DC plus realis-vicis PCR deprehensio ratio MA-(VI) Real-vicis quantitatis scelerisque cycler BIOD CFX96 Real-vicis PCR ratio BIOD CFX Opus XCVI Real-vicis PCR ratio |
ADMODO
Optio I.
Qiaamp viral RNA Mini Ornamentum ((LII) CMIV), nucleic acidum extractionem vel purificationem Reagent (YDP315-R) by Tiangen Biotech (Beijing) Co., Ltd.Et extractionExtraction instructiones debet extrahi, et commendatur extraction volumine est CXL μl et commendatur amet volumine LX μl.
Optio II.
Macro & Micro-test viral DNA / RNA Kit (HWTS, 3004-32, HWTS, 3004-48, HWTS, 3004-96) et Macro & Micro-test automatic nucleic acidum extractor (HWTS, MMMVI). Extractionem extrahi secundum instructiones. Et extraction sample volumine est CC μl, et commendatur amet volumine est 80μl.